Electrophoresis is a crucial technique in molecular biology for the separation of DNA, RNA, and proteins. The Integrated Horizontal Electrophoresis System (SVL-2) is designed to enhance the efficiency and accuracy of these separation processes. In this blog post, we will explore the features, specifications, and benefits of the SVL-2 system, along with a step-by-step guide on its operation.

Product Overview:

 

The SVL-2 Integrated Horizontal Electrophoresis Instrument is primarily used for rapid agarose electrophoresis separation experiments of small DNA and RNA samples. This system is designed to provide precise and reliable results, making it an essential tool for laboratories engaged in molecular biology and biotechnology research.

Product Features

 

  1. Versatile Gel Maker Mold: The integrated gel maker mold can produce four different sizes of gel blocks, catering to various experimental needs.
  2. Blue Light Transilluminator: Equipped with a standard blue light transilluminator, the SVL-2 allows real-time observation of bands during the electrophoresis process, especially when used with the SPW-6S electrophoresis power supply.
  3. Transparent Upper Cover: The transparent cover features a hole design for optimal heat dissipation and observation.
  4. Accurate Operation: The card slot limit function ensures precise operation.
  5. Detachable Components: The electrode holder and electrode head are detachable for easy cleaning and maintenance.

Product structure

Product Specifications:

 

  • Product Number: SVL-2
  • Dimensions: 310 x 150 x 120 mm
  • Gel Tray Specifications: Large gel (120 mm x 120 mm), Wide gel (60 mm x 120 mm), Long gel (120 mm x 60 mm), Small gel (60 mm x 60 mm)
  • Specimen Comb Specifications:
    • 1.0 mm: 25/11 teeth
    • 1.5 mm: 13/6 teeth
    • 2.0 mm: 3/2 teeth
  • Blue Light Wavelength: 470 nm
  • Buffer Capacity: 260 mL
  • Weight: 1 kg
  •  
  •     1   Product numberSVL-2
        2Specifications and Dimensions (LXWXH)310X150X120mm
        3Gel Tray Specifications (LXW)

    Largegel 120mm X 120mm;

    Widthgel 60mmX120mm;

    Longgel 120mm X 60mm;

    Smallgel 60mmX60mm

       4Specimen Comb Specifications

    1.0mm 25/11 teeth

    1.5mm 13/6 teeth

    2.0mm 3/2 tooth

       5Blue light wavelength470nm
       6Buffer capacity260mL
       7Weight1kg

Operation Steps:

 

  1. Preparation

    • Ensure all components are clean and dry.
    • Weigh the appropriate amount of agarose into an Erlenmeyer flask.
    • Add buffer and heat until completely melted, then mix well to make the agarose gel solution.
  2. Gel Making

    • Place the gel maker horizontally and select the appropriate gel tray.
    • Pour the agarose gel solution into the tray and let it solidify at room temperature.
    • Once solidified, remove the sample comb to prepare the gel plate.
  3. Sample Loading

    • Place the prepared gel and tray in the electrophoresis box.
    • Add the running buffer to cover the gel plate.
    • Use a micropipette to add samples to the sample grooves without damaging the gel surface.
  4. Electrophoresis

    • Cover the top according to the correct positions of the positive and negative poles.
    • Insert the electrophoresis wire and select the appropriate voltage to start electrophoresis.
    • Monitor the sample movement and stop the process when bromophenol blue reaches 1 cm from the lower edge.
  5. Observation

    • Use the blue light transilluminator to observe the electrophoresis in real time.

Product Configuration List:

 

  • Horizontal electrophoresis apparatus: 1 set
  • Gel maker: 
  • Sample combs:
    • 1.0 mm (25-tooth/11-tooth): 4
    • 1.5 mm (13-tooth/6-tooth): 1
    • 2.0 mm (3-tooth/2-tooth): 1
    •  
  • Gel trays:
    • 60 mm x 60 mm: 2
    • 60 mm x 120 mm: 1
    • 120 mm x 60 mm: 1
    • 120 mm x 120 mm: 1
    •  
  • Blue light transilluminator: 1 set
 

Product Gallery

Precautions:

 

  1. Safety First: Ensure the electrophoresis apparatus is not powered when setting up. Always cover the apparatus before turning on the power to avoid electric shock.
  2. Cleaning and Maintenance: All parts can be washed with water. Dry them naturally or with absorbent paper. Avoid high-temperature drying to prevent damage.

Conclusion:

 

The SVL-2 Integrated Horizontal Electrophoresis System is a versatile, reliable, and efficient tool for DNA and RNA separation. Its advanced features and user-friendly design make it ideal for laboratories focusing on molecular biology and biotechnology.

Sultan Group Services:

 

At Sultan Group, we are dedicated to providing top-notch molecular biology and biotechnology equipment. Our services extend to logistic shipping, custom clearance, and sourcing of products across various domains. Operating in over 108 countries.

we ensure efficient and reliable sourcing, helping businesses focus on their core operations. We also offer a wide range of products, including all types of acids, molecular biology products and reagents, ELISA kits, chemicals and enzymes, and microbiology and cell lines.

For more information about our products and services, visit our website at Sultan Group.